Are dentin posts biomechanically intensive?: A laboratory and FEA study


BELLİ S., Celik K., Akbulut M. B., GÜNEŞER M. B., ERASLAN O., Eskitaccioglu G.

JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, cilt.28, sa.24, ss.2365-2377, 2014 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 28 Sayı: 24
  • Basım Tarihi: 2014
  • Doi Numarası: 10.1080/01694243.2014.966895
  • Dergi Adı: JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.2365-2377
  • Van Yüzüncü Yıl Üniversitesi Adresli: Evet

Özet

The goal of this laboratory and finite elemental stress analysis (FEA) study was to compare fracture strength of dentin post (DP) with stainless steel and glass fiber posts. Single-rooted teeth were decoronated and restored with ParaPost (PP), i-TFC (TFC), and DPs (n=10). Resin cores were created and loaded until failure (1.0mm/min). The data were analyzed (ANOVA, Tukey, Chi-Square tests). Three-dimensional FEA models of the posts were created and the stress distributions were calculated using Solid Works/Cosmos works structural analysis program. A significant difference was found among the groups (p<0.001). TFC group showed the highest and the DP group showed the lowest fracture resistance (p<0.001). PP created more stress at the root dentin and inside the post. Restoration of roots with glass fiber and DPs may reduce stresses within the core material and the remaining root. However, a fracture-resistant restoration cannot be achieved by using a DP.