The effects of laser and ultrasonic irrigation activation methods on smear and debris removal in traditional and conservative endodontic access cavities


Gündüz H., Özlek E.

Lasers in Medical Science, cilt.38, sa.1, 2023 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 38 Sayı: 1
  • Basım Tarihi: 2023
  • Doi Numarası: 10.1007/s10103-023-03816-z
  • Dergi Adı: Lasers in Medical Science
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Aerospace Database, BIOSIS, Biotechnology Research Abstracts, CINAHL, Communication Abstracts, EMBASE, MEDLINE
  • Anahtar Kelimeler: Conservative endodontic cavity, Laser, Passive ultrasonic activation, Smear layer, Traditional endodontic cavity
  • Van Yüzüncü Yıl Üniversitesi Adresli: Evet

Özet

In this study, it was aimed to evaluate the smear and debris removal efficiency of laser and ultrasonic irrigation activation methods in traditional and conservative endodontic access cavity preparations. 60 freshly extracted human mandibular molar teeth were randomly divided into 2 groups according to the access cavity preparation (n = 30): Traditional endodontic access cavities (TEC) and Conservative endodontic access cavity (CEC). After the access cavity preparation, the mesiobuccal root canals were prepared to 35/0.4 with the VDW Rotate file system. Teeth with completed root canal preparation were randomly divided into 3 subgroups according to the final irrigation activation protocol (n = 30): Conventional needle irrigation, passive ultrasonic activation and laser activation. The crowns of the teeth were removed and the mesiobuccal roots were divided longitudinally into two halves, mesial and distal. Samples were scanned with scanning electron microscopy. Photomicrographs in the coronal, middle, and apical thirds of each specimen were taken at a magnification of 200 for debris and 1000 for evaluation of the smear layer. Data were analysed using the three-way Robust Anova test and Bonferroni test. The effect of access cavity design on remaining smear (p = 0.057) and debris (p = 0.5) was not statistically significant. The effect of the interaction of access cavity and irrigation activation on the remaining smear and debris was not statistically significant (p = 0.556, p = 0.333). Significantly fewer smears were detected in the laser activation group than in the ultrasonic activation and control groups. Conservative access cavities did not differ from conventional access cavities in terms of debris and smear. Graphical Abstract: [Figure not available: see fulltext.].